specification of a water tube boiler

PDF Cleaver-brooks Packaged Watertube Boilers

Boiler is a two drum, bent-tube, "D" type Boiler. The line consists of three Models; "D", "DL" and "DLD" which vary only in size, dimensions, and capacity. All models are covered by this manual. The Boiler has a six-wall water cooled furnace. The inside and outside furnace walls, as well as the floor and roof, are constructed of tangent tubes.

Chat Online
PDF Protecting Out-of-service Steam Boilers

4. Thoroughly dry the water-side surfaces using a forced air heater; 5. Place a desiccant such as calcium oxide (i.e., dehydrated lime), silica gel, or activated alumina in trays and distribute them in the steam drum, and if possible in the mud drum as well for water tube boilers, and on top of the tubes for fire tube boilers.

Chat Online
PDF Ajax Series Atlas Series Product Catalog - Surplus Group

Inclined Water Tube Boilers † Near-Condensing † Condensing Hybrid Systems † Heat Exchangers † Tanks Ajax Series † Atlas Series Product Catalog. Introduction. AJAX BOILER INC. has been in operation since 1919 and, over the years, has developed a strong line of products that

Chat Online
Boiler Feed Water and Boiler Water - EWT Water Technology

EN 12952-12 / Water-tube boilers - Requirements for boiler feed water and boiler water quality; EN 12953-10 / Shell boilers - Requirements for boiler feed water and boiler water quality; national codes and standards: BS 2486 / Recommendations for Treatment of Water for Steam Boilers and Water Heaters (United Kingdom, obsolete)

Chat Online
Applications: Tube, Pipe & Fittings: Copper & Copper Alloy

Copper water tube is a seamless, almost pure copper material manufactured to the requirements of ASTM B 88 - Standard Specification for Seamless Copper Water Tube, of three basic wall thickness dimensions designated as types K, L, and M. Type K is the thickest and type M is the thinnest with type L being of intermediate thickness. All three

Chat Online
ASME Codes and Standards - A summary | welding & NDT

High temperature water tube boilers Certain fired pressure vessels to be used in stationary services SECTION II: Section II is exclusively dedicated to materials and its specifications.

Chat Online
PDF Flexible Watertube Boilers

Information in this section applies to steam and hot water boiler sizes ranging from 1.5 to 12 MMBtu/hr input, as shown in Table B1-1. The Flexible Watertube Boiler is a five-pass steel boiler with flexible tubes formed and arranged to direct the flow of combustion gases through the boiler. The pressure vessel

Chat Online
Babcock and Wilcox Boiler - Construction, Working

4. Water Tubes: They are the tubes in which water flows and gets converted into steam. It exchanges the heat from the hot flue gases to the water. It is inclined at angle of 10-15 degree with the horizontal direction. Due to its inclination the water tubes do not completely filled with water and the water and steam separated out easily.

Chat Online
PDF SAMPLE SPECIFICATION - Superior Boiler

SAMPLE SPECIFICATION for maximum heat transfer while being in contact with the coolest boiler water. 2.3 All boilers constructed to Section I of the A.S.M.E. Code are to have a The tubes on a Section IV boiler are to be attached by flare rolling. 2.5 All tubesheets on Section I boilers are to be a minimum of 3/4 of an inch to insure a

Chat Online
Boiler Fittings and Mountings | Spirax Sarco

The system may be manual or automatic. Whatever system is used, the TDS in a sample of boiler water is compared with a set point; if the TDS level is too high, a quantity of boiler water is released to be replaced by feedwater with a much lower TDS level. This has the effect of diluting the water in the boiler, and reducing the TDS level.

Chat Online
PDF Using Reverse Osmosis for Boiler Pretreatment

Pretreatment 44 Disadvantages of RO as compared to a softener boiler pretreatment program include: x Increased electrical costs. x If acid pretreatment is used, acid handling will be required. x Product water flow rate is pretty much fixed while ion exchange can manage variable flows. x An antiscalant may be necessary upstream of the RO. x With polyamide (PA) membranes, chlorine must be removed

Chat Online
boiler tube specifications, boiler tube specifications

2,027 boiler tube specifications products are offered for sale by suppliers on Alibaba.com, of which steel pipes accounts for 4%. A wide variety of boiler tube specifications options are available to you, such as structure pipe. There are 1,230 suppliers who sells boiler tube specifications on Alibaba.com, mainly located in Asia.

Chat Online
FTXL Fire Tube Boiler | Commercial Boilers | FTXL™ Fire

The FTXL boiler is the new 98% efficiency standard in fire tube technology, and it puts remote connectivity at your fingertips. The FTXL boiler also has a compact footprint of just 6.2 sq. ft. 5 Models from 399,999 to 850,000 Btu/hr

Chat Online
Feed Water - Chemistry Limits - Engineering ToolBox

Feed Water Treatment to Avoid Corrosion - Make-up water to steam boilers should be treated with oxygen scavengers to avoid serious corrosion problems; Maximum Flow Velocities in Water Systems - Water velocities in pipes and tubes should not exceed certain limits; Steam Boiler Rating and Feed Water Temperature - Boiler output and feed water

Chat Online
Water Tube Boiler - Construction, Operation

Special features of water tube boiler: Water tube boilers have the high evaporating capacity (20,000 to 40,000 kg/h) compared with other boilers. The operating pressure lies between 11.5 to 17.5 bar. The draft losses are minimum. The defective tubes in water tube boilers can be identified and replaced easily.

Chat Online
Characteristics of boiler feedwater - Lenntech

Feed-water purity requirements therefore can vary widely. A low-pressure fire-tube boiler can usually tolerate high feed-water hardness with proper treatment while virtually all impurities must be removed from water used in some modern, high-pressure boilers. Only relatively wide ranges can be given as to maximum levels of alkalis, salt, silica

Chat Online
DOCX Section 23 52 33 - WATER-TUBE BOILERS

3.Two types of high pressure water tube boilers are specified, flex tube and D-type. The two boiler types are significantly different, and only one of the two types should typically be specified if all new boilers in a given project are similar. 4.Flex tube boilers: a)Primarily for non-critical service firing gas fuel and with stable steam demands.

Chat Online
BS 1113:1999 - Specification for design and manufacture of

Water-tube boilers and auxiliary installations. Part 8. Requirements for firing systems for liquid and gaseous fuels for the boiler BS 1113:1999 Specification for design and manufacture of water-tube steam generating plant (including superheaters, reheaters and steel tube economizers)

Chat Online
Carbon Steel Plate and Tube for Boilers - ASTM A106|ASTM

ASTM A210. ANSON manufactures 2 ASTM A210 steel grades (A-1, C) of minimum wall thickness and tubing sizes, it is a standard for medium-carbon seamless boiler tubes for superheater, including safety end, vault, supporting pipe and super heater pipe.

Chat Online
Boiler Chemical Cleaning: Doing It Correctly

Please contact [email protected] or call 888-707-5814 (M - Th 9 am - 5:30 pm and F 9 am - 3 pm. ET) , to start a free trial, get pricing information, order a reprint, or post an

Chat Online
Chapter 14 - Boiler System Failures | SUEZ

Straight tube, shell-and-tube waste heat boilers frequently develop tube and tube sheet failures due to the imposition of unequal stresses. A primary cause of this is the uneven distribution of hot gases across the face of the tube sheet.

Chat Online
Water Treatment Requirements for Low and Medium Pressure

Low and medium pressure boilers must be protected from scale deposition and corrosion to promote optimum energy efficiency and prolong the useful life of the plant equipment. The definition of low and medium pressure is somewhat discretionary. For the purposes of this discussion, low pressure shall apply to boilers up to 150 psig. These boilers

Chat Online
Water Handbook - Preboiler & Industrial Boiler Corrosion

The trays are placed in each drum of a water tube boiler, or on the top flues of a fire-tube unit. All manholes, handholes, vents, and connections are blanked and tightly closed. The boiler should be opened every month for inspection of the desiccant.

Chat Online
D Type Water Tube Boilers | Water Tube Boiler Sales & Service

D type watertube boiler design. D type watertube boilers are designed with a large steam drum at the top, vertically connected to a smaller water drum (or "mud drum") at the bottom, via multiple steam-generating tubes which carry feed water (providing the main heat transfer surfaces for the production of steam).

Chat Online
Division 23 52 33.13 Water-tube Condensing Boilers Part 1

2. Product: XTherm™ condensing water-tube hydronic boiler(s) 2.2 BOILERS A. General 1. The boiler(s) shall be fired with gas at a rated input of BTU/hr. 2. The boiler(s) shall be CSA tested and certified with a minimum thermal efficiency of 96 percent at full fire (99% at part load). 3.

Chat Online
Technical Papers - American Boiler Manufacturers Association

Boiler Water Limits and Achievable Steam Purity for Water-Tube Boilers standard by American Boiler Manufacturers Association , 01/01/1995. Historical Editions: ABMA-Boiler 402 , ABMA-Boiler 400

Chat Online
PDF Chapter 14 Boilers - Pearson Education

Superheater—tubes located near the boiler outlet that increase (superheat) the temperature of the steam, p. 297. Waste heat boiler—a device that uses waste heat from a process to produce steam, p. 297. Water tube boiler—a type of boiler that contains water-filled tubes that allow water to circulate through a heated firebox, p. 296.

Chat Online
Industrial Water-tube Package Boilers

Our industrial water-tube package boilers are custom-engineered to each project's unique specifications for varying inputs and desired outputs. All of our designs feature the high levels of quality, reliability and efficiency for which B&W is known. Over the years, B&W's industrial boiler configurations have been known by various

Chat Online
Boiler Formulas - Johnston Boiler

Boiler Horsepower What is the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at 155 psi? The factor of evaporation is 1.08. BHP = (LB/HR*fe)/34.5 BHP Boiler Horsepower BHP = (LB/HR*fe)/34.5 Lb/Hr Pounds per Hour BHP = 21500 * 1.08 / 34.5 Fe Factor of Evaporation BHP = 673 Cycle

Chat Online
How Boiler Pipe is Manufactured, Material Specification

Boiler Pipe Material Specification and Application. tube exchanger bundle, high pressure boiler, economizer, super heater, petrochemical industry pipes, etc. then quickly immerse in water or oil for rapid cooling, and cooling in the air or in the freezing zone. So that the high pressure boiler pipe can obtain the required hardness.

Chat Online
The Metallurgy of Power Boilers - National Board of Boiler

As an aside, all hot forming and shaping employed to make boiler tubes and piping is done in the austenite temperature range of 1650 o F to 2000 o F. With the continued cooling, the face-cantered-cubic austenite begins to transform to body-centered-cubic ferrite at a temperature of around 1600 o F, and again, the exact temperature depends on

Chat Online
PDF VA 23 52 33 Water-Tube Boilers - WBDG | WBDG

3. Two types of high pressure water tube boilers are specified, flex tube and D-type. The two boiler types are significantly different, and only one of the two types should typically be specified if all new boilers in a given project are similar. 4. Flex tube boilers: a) Primarily for non-critical service firing gas fuel and with stable steam

Chat Online
PDF Scotch Marine Firetube Steam Boiler Manual

TOT: Top of tubes; the highest point in the boiler where flue gas passes though tubes. Set point: A specific value of pressure or temperature used in a control where it will switch on or off. Aquastat: Water temperature control device BoHP: Boiler horse power: The evaporation of 34.5 lbs of water/hr. from a temperature of 212°F into dry

Chat Online
Operation and Types of Water Tube Boiler - Electrical4U

A water tube boiler is such kind of boiler where the water is heated inside tubes and the hot gasses surround them. This is the basic definition of water tube boiler. Actually this boiler is just opposite of fire tube boiler where hot gasses are passed through tubes which are surrounded by water.. Advantages of Water Tube Boiler. There are many advantages of water tube boiler due to which

Chat Online
Cleaver-Brooks Boilers (industrial) Data Sheets

Firetube Boiler -- 4WG: Integrated package includes pressure vessel, ProFire® packaged burner, and controls for optimal fuel-to-steam/water efficiency, space savings, and low emissions.

Chat Online
power plant boiler specification - Water Tube Boiler

PROCESS DESIGN OF STEAM BOILERS (PROJECT STANDARDS AND SPECIFICATIONS) Page 3 of 45 Rev: 01 April 2011 SCOPE This Project Standards and Specifications is intended to cover minimum requirements for process design of field erected water tube boilers.

Chat Online
specification of water tube boiler - v-shape.be

Water-tube boiler - Wikipedia. 2019-5-16 · A high pressure watertube boiler[1] (also spelled water-tube and water tube) is a type of boiler in which water circulates in tubes heated externally by the fire. Fuel is burned inside the furnace, creating hot gas which heats water in the steam-generating tubes.

Chat Online
Specification For Water Tube Boiler

Specification For Water Tube Boiler - Water-tube boiler - Wikipedia. A high pressure watertube boiler (also spelled water-tube and water tube) is a type of boiler in which water circulates in tubes heated externally by the fire. Fuel is burned inside the furnace, creating hot gas which heats water in the steam-generating tubes. Learn More

Chat Online
PDF BOILER WATER TREATMENT - Sensorex - Your Water

steam circulates. (Refer Figure 2.2). Fire tube boilers, typically have a lower initial cost, are more fuel efficient and easier to operate, but they are limited generally to capacities of 25 tons/hr and pressures of 17.5kg/cm2. Water Tube Boiler: Water tube or "water in tube" boilers in which the

Chat Online
PDF Process Design of Steam Boilers (Project Standards and

PROCESS DESIGN OF STEAM BOILERS (PROJECT STANDARDS AND SPECIFICATIONS) Page 3 of 45 Rev: 01 April 2011 SCOPE This Project Standards and Specifications is intended to cover minimum requirements for process design of field erected water tube boilers. REFERENCES Throughout this Standard the following dated and undated standards/codes are referred to.

Chat Online